+++++++ SURGICAL EQUIPMENT +++++++

|
Digital 1-channel Electrocardiograph
Item Number: EKG-901
Features:
- 12-lead simultaneous standard resting ECG
- One-touch operation
- Concept of floating input circuit meets IEC safety standard
- High-resolution thermal printing array system
- Frequency response is as high as 150Hz
- Capable of printing continuously on channel trace and annotations including lead mark and parameter such as sensitivity, paper speed and filter operation status
- High resolution digital filter inhibits baseline drift without affecting ECG waveform
- Rechargeable battery supporting more than 50 patient examinations
Specification:???
Safety standard |
IEC60601-1 class I, type CF |
Input circuit |
Floating; Protection against Defibrillator effect |
Lead |
Standard 12 Leads, Lead change automatically |
Patient current leakage |
<10米A |
Input impedance |
≡10收次? |
Calibrating voltage |
1mV㊣3%? |
A/D conversion? |
?12 bit? |
Frequency response? |
0.05Hz~150Hz (IEC) |
Time constant? |
>3.2seconds? |
CMRR |
>80dB |
? |
>100dB (with filter) |
EMG filter? |
35Hz (-3dB) / 25Hz (-3dB)? |
Sensitivity |
1/2, 1, 2 (cm/mV), Conversion Deviation≒5% |
Recording system? |
Thermal-array |
? |
8 dots/mm ( vertical )? |
? |
16 dots/mm ( horizontal, 25mm/sec ) |
Paper speed?? |
25, 50mm/s㊣3% |
Recording paper? |
50mm,20m, high-speed roll |
Input circuit current |
≒50nA??? |
Power supply |
AC: 220V / 110V, 50/60Hz
DC: 12V rechargeable battery? |
Skin voltage tolerance |
㊣300mV |
Noise level |
<15uVp-p |
Dimensions? |
310℅230℅70mm? |
Dimension of packing |
400℅280℅160mm |
Weight |
2.75kg |
|
|
Digital 1-channel Electrocardiograph
Item Number: EKG-901A
Features:
Specification:????
Input Circuit |
Floating; Protection against defibrillator effect |
Lead |
Standard 12 Leads, Lead change automatically |
Number of dots (LCD) |
240 x 128 |
Patient Current Leakage |
<10米A |
Input Impedance |
≡10收次 |
Calibrating Voltage |
1mV㊣3% |
A/D Conversion |
12 bit |
Frequency Response |
0.05Hz~150Hz (IEC) |
Time Constant |
>3.2seconds |
CMRR |
>80dB
>100dB (with filter) |
EMG Filter |
35Hz (-3dB) / 25Hz (-3dB) |
Sensitivity |
1/2, 1, 2 (cm/mV), Conversion Deviation≒5% |
Recording System |
Thermal-array |
8 dots/mm ( vertical ) |
16 dots/mm ( horizontal, 25mm/sec ) |
Paper Speed |
25, 50mm/s㊣3% |
Recording Paper |
50mm, 30m, high-speed roll |
Input Circuit Current |
≒50nA |
Safety Standard |
IEC class I, type CF |
Power Supply |
AC 80~250V, 50/60Hz㊣1Hz
DC 12V/1800mAh 15VA, rechargeable battery |
Skin Voltage Tolerance |
㊣300mV |
Noise Level |
<15米Vp-p |
Dimension |
31cm*23cm*7cm |
Net Weight |
2.85kg |
|

|
Digital 3-channel Electrocardiograph
Item Number: EKG-903
Features:
- 12-lead simultaneous standard resting ECG
- One-touch operation
- Concept of floating input circuit meets IEC safety standard
- High-resolution thermal printing array system
- Frequency response is as high as 150Hz
- Capable of printing continuously on channel trace and annotations including lead mark and parameter such as sensitivity, paper speed and filter operation status
- High resolution digital filter inhibits baseline drift without affecting ECG waveform
- Rechargeable battery supporting more than 50 patient examinations
Specification:???
Safety standard |
IEC class I, type CF |
Input circuit |
Floating; Protection against Defibrillator effect |
Lead |
Standard 12 Leads, Lead change automatically |
Patient current leakage |
<10米A |
Input impedance |
≡10收次? |
Calibrating voltage |
1mV㊣3%? |
A/D conversion? |
?12 bit? |
Frequency response? |
0.05Hz~150Hz (IEC) |
Time constant? |
>3.2seconds? |
CMRR |
>80dB |
? |
>100dB (with filter) |
EMG filter? |
35Hz (-3dB) / 25Hz (-3dB)? |
Sensitivity |
1/2, 1, 2 (cm/mV), Conversion Deviation≒5% |
Recording system? |
Thermal-array |
? |
8 dots/mm ( vertical )? |
? |
16 dots/mm ( horizontal, 25mm/sec ) |
Paper speed?? |
25, 50mm/s㊣3% |
Recording paper? |
50mm,20m, high-speed roll |
Input circuit current |
≒50nA??? |
Power supply |
AC: 220V / 110V, 50/60Hz |
? |
DC: 12V rechargeable battery? |
Skin voltage tolerance |
㊣300mV |
Noise level |
<15uVp-p |
Dimensions? |
310℅230℅70mm? |
Dimension of packing |
400℅280℅160mm |
Weight |
2.75kg |
|

|
Digital 3-channel Electrocardiograph
Item Number: EKG-903A
Features:
- Three channel digital ECG machine with interpretation
- Simultaneous acquisition of 12-lead ECG signal
- 8 patient save/copy/communication
- 320x240 graphic, 3.8 inch screen large LCD display
- High resolution thermal printing system
- High resolution digital filter
- One-touch Operation
- Rhythm lead to observe the abnormal ECG waveform and heart rate
- Multiple printing modes
- Built-in RS232 and optional USB interface
- AC/DC power, built-in rechargeable Ni-MH battery
- Light weight with hided handle
Specification:???
Safety classification |
IEC60601-1 class I, type CF |
Lead |
Standard 12 leads |
lead acquisition |
Synchronously 12 leads |
Data acquisition |
18bit/1000Hz |
LCD display |
320℅240 graphic LCD, display status&waveform. |
Record mode |
Manual mode, ?AUTO1, AUTO2, AUTO3 |
Filter |
AC, EMG, Drift Fliter |
CMRR |
≡100dB(with AC filter) |
Input circuit |
Floating; Protection circuit against Defibrillator effect |
Input circuit current |
≒0.1米A |
Input Impedance |
≡50M次 |
Patient current leakage |
ˉ10米A |
Calibrating voltage |
1mV㊣2ㄔ |
Voltage tolerance |
㊣500mV |
Time constant |
ˇ3.2s |
Frequency response |
0.05 ~150Hz |
Noise level |
≒15米Vp-p |
Sensitivity valve |
≒20米V |
Inter-Channel Interference |
≒0.5mm |
Paper speed |
25﹜50mm/s(㊣3ㄔ) |
Sensitivity |
AUTO, 2.5, 5, 10, 20mm/mV |
Recording mode |
Thermal Array printing |
Paper specification |
63mmx30m, high sped paper roll |
Power supply |
AC: 80~250V, 50/60Hz㊣1Hz, 30VA
DC: 14.4V(2000mAh) rechargeable Li-ion battery |
Dimension |
31cm*23cm*7cm |
Net Weight |
2.85kg |
|

|
Digital 6-channel Electrocardiograph
Item Number: EKG-1206
Features:
- Portable, compactㄛflexible and convenient to use
- Can measure, display and record standard 12-lead ECG waveforms.
- 6 channel with measurement report
- 5.6 inch single-color LCD: high light and high definition
- can display electrocardiogram wave and rhythm of heart and catch record opportunity
- Built-in rechargeable Ni-MH battery. Non-memory rechargeable battery to ensure continuous use of the device?
- Chinese/English language.
- Measuring storage and review functions. Automatically saves records when user finishes printing every time. Each record has a maximum time of 50 seconds.
- Against high frequency electrosurgical generator equipment and defibrillation-proof
- Record means: automatic channel connecting means, manual channel
- Connecting means; 6-lead, 3+1-lead, 3-lead electrocardiogram, long time rhythm channel connecting record and periodical record.
- Real time record: record waves for 10s according to channel connecting
- 50/63/110/210mm recorder, can record 3-lead and 6-lead electrocardiogram.
- Web recording paper is more convenient
- Can be used to the physiological measure for adult, child and neonate.
Screen
Size |
Catercorner 5.6 inches |
Type
Single Color |
LCD |
Resolution Ration |
320*240 |
???????????????
? Control
Criterion |
4 direction keys (F1-F4), Power supply switch key, Storage key, Print Start/Stop key. |
?
?
Usable standard leads |
i,j,k, V1, V2, V3, V4, V5, V6, aVR, aVL and aVF |
Lead fail |
Identify the failed lead. |
Alarm |
No alarm |
Input Impedance: |
≡25M次 |
Voltage Range: |
㊣300mV |
Common mode rejection ratio |
≡90dB |
Frequency Respond:
Interior noises: |
0.05Hz~150Hz﹛﹛ 0.4db-3db |
Standard Precision: |
10mm /1mV㊣2% |
?Paper Recorder
Method: |
Dot matrix |
Level Resolution Rationㄩ |
40 d/mm ㄗspeed 25mm/sㄘ |
Uprightness Resolution Rationㄩ |
8 d/mm |
Wave Channelsㄩ |
3/6 |
Paper Widthㄩ |
110mmㄗ4.33inchesㄘ |
Paper Lengthㄩ |
15mㄗ50inchesㄘ |
Formfeed Speedㄩ |
5, 10, 12.5, 25 and 50mm/sㄗ㊣2ㄔㄘ |
Environment Instructions
Power Supply Requirement: |
ACㄩ120V~240V 50Hz/60Hz |
Battery: |
NI-MH , 12V, 1.8AHㄗmodel:205305ㄘ |
Fuse: |
2.0AㄛF2L 250V |
Design(Routineㄘㄩ |
Continuous operation, nonㄜingress of liquids Device. |
Battery lifeㄩ |
When in ECG monitoring, the normal working time are 3 hours for fully charged battery.( Battery aging will reduce the using time) |
?
Battery charged for more than 90ㄔcharging timeㄩ |
6 ~ 12 hours |
Operation Conditionsㄩ
Surrounding Temperaturesㄩ
Relevant humidityㄩ
Atmospheric Pressureㄩ |
?
10 ~ 40⊥
25‵95ㄔ(No Condensation)
700 ~ 1060hPa |
Restore Conditionsㄩ
Surrounding Temperature:
Relevant humidityㄩ
Atmospheric Pressureㄩ |
?
-20⊥‵55⊥
≒93%
500hPa ~1060hPa |
|

|
Digital 12-channel Electrocardiograph
Item Number: EKG-1212
EKG-1212 can show patients* ECG waveform and heart rate clearly and make efficiently examine of the connection state and error information. It can? record the abnormal signal instantaneously, which is helpful in checking out patient condition. The device adopts Chinese/English menu, and it is easy to be operated. Wherever you are and whenever you want, you can have a body check.
Features:
- 8.4** TFT screen with high resolution
- standard 12-lead ECG waveform
- Easy and convenient to operate
- Large LCD screen for easy observation of various lead waveforms.
- Automatic analysis : based on arrhythmia leads
- Automatic printing
- Patients* name, age, ID, weight input etc.
- It is manually editable, which makes the analysis result more accurate.
- Recording methods: automatic lead recording, manual recording, automatic recording, arrhythmia analysis recording (optional), data statistics, single key swift recording and selection recording.
- Build-in chargeable battery, able to continue operating the device when there is no AC power supply temporarily.
- 21cm printer can record 12-lead ECG waveform simultaneously. And the rolling paper is easy to replace.
- The device is smart and flexible to use and carry, especially suitable for hospitals, first-aid centers, sickrooms and collectivity check.
Optional function
- Having measurement storage and review function after it*s equipped with extended memory card.
- The memory card can store 200 groups of 12-lead ECG waveforms and each group is no longer than 50 seconds.
- Recording method: automatic recording, manual recording, arrhythmia recording, automatic analysis recording and simple analysis recording.
Standard configuration:
- Mainframe
- ECG cable
- Limbs electrodes(Containing 4 pieces to match ECG cables)
- Chest electrodes(Containing 6 pieces to match ECG cables)
- Papal roll
- Power cable
- Ground wire
- Operation manua
??
Specification:???
Electric shock protection: |
Class I with internal power |
Electric shock protection degree |
type CF |
Environment temperature range |
+10⊥‵+40⊥ |
Relative humidity range |
30%‵75% |
Atmosphere pressure range |
700 hPa‵1060hPa |
Input resistance |
≡50M次 |
Print resolution |
Y axis ≡8 points/mm,
X axis≡16 points/mm(speed of paper 25mm/s)
X axis≡8 points/mm( speed of paper 50mm/s) |
Recording sensitivity |
standard sensitivity 10mm/mV
allowance inaccuracies ㊣2% |
Sensitivity shift of inaccuracy range |
㊣5% |
Degree of preventing entry of harmful water |
common device |
Operation mode |
continuous operation |
Screen show:
? |
|
|
|
|
|
|
|